Longitudinal Barriers Products
New and full-replacement installations must use MASH-compliant systems.
MASH High-Tension Cable Barrier
Proprietary MASH high-tension cable barrier (HTCB) systems are engineered systems subject to MnDOT’s Approved/Qualified Products Policy.
Product | Manufacturer | Approval Date | Notes |
---|---|---|---|
MASH 2016 Cable System | Gibraltar Global | March 17, 2025 | Approved for 1V:4H or flatter cross slope. |
O-Post 4 Rope System | Brifen USA | March 17, 2025 | Approved for 1V:6H or flatter median slope and 1V:4H or flatter outside roadside slope. |
Qualified Foundation Designs for MASH HTCB
MASH HTCB systems must employ qualified anchor, terminal post, and line post foundation designs compatible with the HTCB system and site-specific soil information from the Soils Data Report. See the Guidance section of this page for the Qualification Requirements for MASH HTCB Foundations. Foundation designs that have already been evaluated as meeting the qualification requirements are listed in the Qualified Foundation Designs table, below. Additional foundation designs may be available from the manufacturer but require qualification before use.
Name* | Compatible System(s) | Foundation Type | Qualification Date | Minimum Soil Properties | Other Restrictions, if Applicable |
---|---|---|---|---|---|
Example | System Name(s) | Line post, terminal post, or anchor | Shear strength and unit weight of cohesive soil; friction angle and unit weight of noncohesive soil; minimum depth to normal water table; maximum assumed frost depth. | E.g. if minimum radius for 10-foot spacing differs from 250 ft. |
* See links for drawings and specifications.
NCHRP 350 High-Tension Cable Barrier
NCHRP 350 systems are available only for maintenance.
Product | Manufacturer | Approval Date |
---|---|---|
Brifen TL-4 (4-Rope) WRSF | Brifen | 8/22/2012 |
Gibraltar TL-4-4-Cable Barrier System | Gibraltar | 8/22/2012 |
Composite/Plastic Block-outs **
Manufacturer | FHWA Eligibility Letter 8” Block Depth NCHRP 350 *** |
FHWA Eligibility Letter 8” Block Depth MASH |
FHWA Eligibility Letter 12” Block Depth MASH |
Approval Date |
---|---|---|---|---|
Mondo Polymer Technologies | B-39B | B-39D B-278A |
B-39C | 10/11/2019 |
Valtir, LLC | B-85E | - | - | 11/9/2016 |
Valtir, LLC | - | B-342 | B-353 | 12/23/2021 |
** Installer shall assume all responsibility for proper application and adherence to the manufacturer's installation instructions.
***Product may be used on in-place NCHRP 350 systems requiring replacement or maintenance.