Signal Systems Asset Class
Signals As-built Survey Data Template
Signal Systems Template (Excel) standardizes the deliverable format for below Index.
Signals Feature Collect Index
For cables and conduits, use unique ID per run.
| File | Feature Class | Signals Features (Code) | Coordinates collect point | Attribute Collect Information |
|---|---|---|---|---|
| Signals As-built Survey Data Template | Cables and Conduit | Fiber Optic Cable - Direct Buried (FO); Fiber Optic Cable in Conduit (FOCD); Signal Power Cable in Conduit (ECIC); Underground Signal Interconnect – Copper (USI) | Once every 50', at edge of pavement for roadway crossings, and at change in direction | 1. Plan ID 2. Comments |
| Signals As-built Survey Data Template | Devices | Camera (CAM); Traffic Signal Pole (SGL);Signal Ped Pole (SGLPED); Power Pole (EP); Advanced Warning Flasher (AWFPED); Push Button Walk (PWB) | At Pole Roadway Side | 1. Plan ID 2. Comments |
| Signals As-built Survey Data Template | Structures | Signal Cabinet (SIGCAB); Transformer (TRANS) | At Structure Cable Entry Point | 1. Plan ID 2. Comments |
| Handhole (EHH) | At Structure Top Center | Signal Cabinet (SIGCAB); Transformer (TRANS) | At Structure Cable Entry Point | 1. Plan ID 2. Comments |
Signal Systems Deliverable Example
Example 1: Typical Signals improvement project
References
Legacy TABLE Z (Excel) format will be accepted until phased out of contracts.